Omicron CMC256-6 Relay Test Set – Advanced, Universal and Protection. The CMC 256-6 is the first choice for applications requiring very high accuracy. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator. Its high precision allows the calibration of a wide range of measuring devices.
The CMC 256plus is the first choice for applications requiring very high accuracy. This unit is
not only an excellent test set for protection devices of all kinds but also a universal calibra-
tion tool. Its high precision allows the calibration of a wide range of measuring devices,
including: electricity meters of class 0.2, measuring transducers, power quality measurement
devices and phasor measurement units (PMU). Its unique accuracy and flexibility make the
CMC 256plus ideal for protection and measurement equipment manufacturers for research
and development, production and type testing. The CMC 256plus can either be operated by
the Test Universe software running on a PC or by the front panel control device CMControl.
CMC 256plus: 6 Phase Current + 4 Phase Voltage Test Set and Universal Calibrator
Current generators
Setting range 6-phase AC (L-N)
6 x 0 .. 12.5 A
3-phase AC (L-N)
3 x 0 .. 25 A (Group A II B)
1-phase AC (3L-N)
1 x 0 .. 75 A (Group A II B), 2 x 0 .. 37.5 A
DC (3L-N)
1 x 0 .. ±35 A (Group A II B), 2 x 0 .. ±17.5 A
Power
6-phase AC (L-N)
6 x 80 VA typ. at 8.5 A, 6 x 70 VA guar. at 7.5 A
3-phase AC (L-N)
3 x 160 VA typ. at 17 A (Group A II B)
3 x 140 VA guar. at 15 A (Group A II B)
1-phase AC (3L-N)
1 x 480 VA typ. at 51 A (Group A II B),
2 x 240 VA at 25.5 A
1 x 420 VA guar. at 45 A (Group A II B),
2 x 210 VA at 22.5 A
1-phase AC (L-L)
1 x 320 VA typ. at 8.5 A (Group A II B),
2 x 160 VA at 8.5 A
1 x 280 VA guar. at 15 A (Group A II B),
2 x 140 VA at 7.5 A
1-phase AC (L-L-L-L) 1 x 320 VA typ. at 8.5 A
(40 VRMS, Group A and B in series)
1 x 280 VA guar. at 7.5 A
(40 VRMS, Group A and B in series)
DC (3L-N)
1 x 480 W typ. at ±35 A (Group A II B),
2 x 240 W at ±17.5 A
1 x 470 W guar. at ±35 A (Group A II B),
2 x 235 W at ±17.5 A
500
400
300
200
100
0
0
10
25
50
75
Output current / A
Group A
and B in
series
1-phase
AC (L-L)
3-phase AC (L-N)
1-phase AC (L-N)
Output po
w
er (typ.) / V
A
Accuracy
2
error < 0.015 % rd.
3
+ 0.005 % rg.
3
typ.
at 0 .. 12.5 A
error < 0.04 % rd. + 0.01 % rg. guar.
at 0 .. 12.5 A
Distortion (THD+N)
4
< 0.025 % typ., < 0.07 % guar.
Ranges
1.25 A / 12.5 A (Group A, B) or
2.5 A / 25 A (Group A II B)
Resolution (for respective range)
50 µA / 100 µA / 500 µA / 1 mA
Max. compliance voltage (L-N)/(L-L) 15 Vpk / 60 Vpk
Connection
4 mm (0.16 in) banana sockets / combination
socket (Group A only)
Voltage generators
Setting range
4-phase AC (L-N)
4 x 0 .. 300 V (VL4(t) automatically
calculated: VL4 = (VL1+VL2+VL3)*c
or freely programmable)
3-phase AC (L-N)
3 x 0 .. 300 V
1-phase AC (L-L)
1 x 0 .. 600 V
DC (L-N)
4 x 0 .. ±300 V
Power
3-phase AC (L-N)
3 x 100 VA typ. at 100 .. 300 V
3 x 85 VA guar. at 85 .. 300 V
4-phase AC (L-N)
4 x 75 VA typ. at 100 .. 300 V
4 x 50 VA guar. at 85 .. 300 V
1-phase AC (L-N)
1 x 200 VA typ. at 100 .. 300 V
1 x 150 VA guar. at 75 .. 300 V
1-phase AC (L-L)
1 x 275 VA typ. at 200 .. 600 V
1 x 250 VA guar. at 200 .. 600 V
DC (L-N)
1 x 420 W typ. at ±300 V
1 x 360 W guar. at ±300 V
Output voltage / V
Output po
w
er (typ.) / V
A
1-phase AC (L-L)
1-phase AC (L-N)
3-phase AC (L-N)
4-phase AC (L-N)
300
250
200
150
100
50
0
0
100
200
300
400
500
600
Accuracy
5
error < 0.015 % rd.
3
+ 0.005 % rg.
3
typ. at 0 .. 300 V
error < 0.04 % rd. + 0.01 % rg. guar.
at 0 .. 300 V
Distortion (THD+N)
4
0.015 % typ., < 0.05 % guar.
Ranges
150 V / 300 V
Resolution
5 mV / 10 mV in range 150 V / 300 V
Connection
4 mm (0.16 in) banana sockets /
combination socket (1,2,3,N)
Generators, general
Frequency
range sine signals Ipod shuffle generation 4 user manual.
10 .. 1000 Hz
range harmonics /
interharmonics
6
10 .. 3000 Hz
range transient signals
6
DC .. 3.1 kHz
accuracy / drift
±0.5 ppm / ±1 ppm
resolution
< 5 µHz
Phase
angle range
-360° .. +360°
resolution
0.001°
error at 50 / 60 Hz
< 0.005° typ., < 0.02° guar.
Bandwidth (-3 dB)
3.1 kHz
Simulated power
S, P (calibration
of energy meters)
accuracy
7
error < 0.05 % rd. typ., < 0.1 % rd.
guar.
temperature drift
< 0.001 % / °C typ., < 0.05 % / °C guar.
Technical Data
1
1
All data specified are guaranteed, except where indicated otherwise.
OMICRON guarantees the specified data for one year after factory calibration,
within 23 °C ±5 °C (73 °F ±10 °F) in the frequency range from 10 to 100 Hz and
after a warm-up phase > 25 minutes
2
Rload: 0 .. 0.5 W
3
rd. = reading, rg. = range
4
THD+N: Values at 50/60 Hz, > 1 A / 20 V with 20 kHz bandwidth
5
Rload: > 250 W
The shine of stainless steel and the glint of glass accented with sturdy grates and Euro-styled handles. Haier washer model hlp28e user manual. These arent your grandmothers appliances. Theyre made for people like you who want to take care of the menial and get back to the meaningful without sacrificing style. Haier designs inspired appliances with features youll want to post aboutand with looks youll want to show off. Haier America offers affordable, quality, energy efficient air conditioners, televisions, refrigerators, washers and other home, laundry and kitchen appliances.
6
Amplitude derating at > 1000 Hz
7
Data are valid from 0.1 to 12.5 A (current amplifier A or B) and 50 to 300 V
(voltage amplifier) at 50/60 Hz
Permissible load for current outputs:
Range 1.25 A: 0 to 1 W and 1 VA max., cos ϕ = 0.5 to 1
Range 12.5 A: 0 to 0.5 W and 6 VA max., cos ϕ = 0.5 to 1
Permissible load for voltage outputs:
10 VA max. at 50 to 300 V, cos ϕ = 0.5 to 1
CMC 256plus
Miscellaneous
Weight
15.9 kg (35 lbs)
Dimensions (W x H x D, without handle) 450 x 145 x 390 mm (17.7 x 5.7 x 15.4 in)
PC connection
Two 10/100 Mbit/s PoE
4
Ethernet ports:
• 10/100 Mbit/s (10/100 Base-TX,
auto-sensing, auto-crossover, RJ45
connector for twisted pair cables)
• IEEE 802.3af compliant
• Port capability limited to one Class 1
(3.84 W) and one Class 2 (6.49 W)
powered device
If equipped with PAR-1 option: Parallel
port (IEEE 1284-C connector). Replaces
the standard Ethernet interfaces by a
parallel port if required by the used PC or
if the binary extension device CMB IO-7
should be used
5
Signal indication (LED)
> 42 V for voltage outputs and AUX DC
Connection to ground (earth)
4 mm (0.16 in) banana socket (rear side)
Hardware diagnostics
Self diagnostics upon each start-up
Galvanically separated groups
The following groups are galvanically
separated from each other: mains, volt-
age amplifier output, current amplifier
group A/B, auxiliary DC supply, binary/
analog input
Protection
All current and voltage outputs are fully
overload and short circuit proof and
protected against external high-voltage
transient signals and over temperature
Certifications
Developed and manufactured under an
ISO 9001 registered system
Technical Data CMC 256plus (continued)
IEC 61850 GOOSE
1
Simulation
Mapping of binary outputs to data attributes in
published GOOSE messages.
Number of virtual binary outputs: 360
Number of GOOSEs to be published: 128
Subscription
Mapping of data attributes from subscribed GOOSE
messages to binary inputs.
Number of virtual binary inputs: 360
Number of GOOSEs to be subscribed: 128
Performance
Type 1A; Class P2/3 (IEC 61850-5).
Processing time (application to network or vice versa):
< 1 ms
VLAN support
Selectable priority and VLAN-ID
IEC 61850 Sampled Values (Publishing)
1
Specification
According to the “Implementation Guideline for
Digital Interface to Instrument Transformers Using
IEC 61850-9-2“ of the UCA International Users Group
Sampling Rate
80 samples per cycle for nominal frequencies of 50
Hz and 60 Hz; synchronized with CMIRIG-B.
Synchronization
Synchronization attribute (smpSynch) is set when
the CMC is in synchronized operation mode utilizing
CMIRIG-B.
Sample count (smpCnt) zero is aligned with top of
the second (IRIG-B and PPS)
Accuracy data see above
VLAN support
Selectable priority and VLAN-ID
Max. number of SV streams 2 (with option LLO-2: 3 SV streams)
Power supply
Nominal input voltage
2
100 – 240 VAC, 1-phase
Permissible input voltage
85 .. 264 VAC
Nominal frequency
50/60 Hz
Permissible frequency range 45 .. 65 Hz
Power consumption
1.4 kVA at 115 V
/ 2.3 kVA at 230 V
Rated current
12 A at 115 V / 10 A at 230 V
Connection
Standard AC socket (IEC 60320)
Environmental conditions
Operation temperature
3
0 .. +50 °C (+32 .. +122 °F)
Storage temperature
-25 .. +70 °C (-13 .. +158 °F)
Humidity range
Relative humidity 5 .. 95 %, non-condensing
Vibration
IEC 60068-2-6 (20 m/s
2
at 10 .. 150 Hz)
Shock
IEC 60068-2-27 (15 g/11 ms half-sine)
Safety Standards, Electromagnetic Compatibility
EMC
The product adheres to the electromagnetic compat-
ibility (EMC) Directive 2004/108/EC (CE conform).
Emission
Europe EN 61326-1; EN 61000-6-4; EN 61000-3-2/3
International IEC 61326-1;IEC 61000-6-4; IEC 61000-3-2/3
USA FCC Subpart B of Part 15 Class A
Immunity
Europe EN 61326-1; EN 61000-6-2;
EN 61000-4-2/3/4/5/6/11
International IEC 61326-1;IEC 61000-6-2;
IEC 61000-4-2/3/4/5/6/11
Safety
The product adheres to the low voltage Directive
2006/95/EC (CE conform).
Europe EN 61010-1 Insulation of PC and SELV interfaces
complies with EN 60950-1
International IEC 61010-1
USA UL 61010-1
Canada CAN/CSA-C22.2 No 61010-1-04
1
Testing with GOOSE and Sampled Values functionality requires software licences for
the corresponding configuration modules
2
For line inputs below 115 VAC, it is not possible to drive all outputs (voltage
output, current output, Aux DC) simultaneously at full load. All other technical
specifications (e.g. the maximum output power of a single amplifier) are not
affected
3
For an operational temperature above +30 °C (+86 °F) a duty cycle of down to
50 % may apply
4
PoE = Power over Ethernet
5
CMC 256plus with PAR-1 option is connected to the USB port of the PC by means
of the parallelport cable and the CMUSB-P (USB to Parallel Port Converter).
CMC 256plus equipped with the PAR-1 option can not be extended with the LLO-2
option and does not support the CMIRIG-B accessory
Ordering Information
CMC 256plus with Test Universe Software
VE002701
CMC 256plus Basic
VE002702
CMC 256plus Protection
VE002703
CMC 256plus Advanced Protection
VE002704
CMC 256plus Universal
VE002705
CMC 256plus Meter
VE002706
CMC 256plus Measurement
CMC 256plus with CMControl (without Test Universe Software)
VE002715
CMC 256plus with CMControl-6
The CMControl can also be ordered as add-on together with a
CMC 256plus with Test Universe software or as a later upgrade.
CMC 256plus Hardware Options
VEHO2703
Option LLO-2 if ordered with a new unit
VEHO2704
Option LLO-2 if ordered as an upgrade
VEHO2701
Option PAR-1 if ordered with a new unit
5
VEHO2702
Option PAR-1 if ordered as an upgrade
5